8544 42 – Electric conductors up to 1,000 V fitted with connectors: patch cables, connecting cables, cable assemblies
Subheading 8544 42 covers insulated electric conductors for a voltage not exceeding 1,000 V that are fitted with connectors. This includes patch cables, network cables, device connection cables, adapter cables and solar cables with connectors. The 8-digit code depends on whether the cable is of a kind used for telecommunications (8544 42 10) or not (8544 42 90).
- CN description
- Insulated (including enamelled or anodised) wire, cable (including coaxial cable) and other insulated electric conductors, whether or not fitted with connectors; optical fibre cables, made up of individually sheathed fibres, whether or not assembled with electric conductors or fitted with connectors – Fitted with connectors
- Commodity codes
- 8544 42 108544 42 90 · Status: Combined Nomenclature 2026
The 8-digit commodity codes of subheading 8544 42
In the export declaration you enter the 8-digit code.
| Code | CN description | Product examples |
|---|---|---|
| 8544 42 10 | Of a kind used for telecommunications |
|
| 8544 42 90 | Other (other than 8544 42 10) |
|
The product examples show which goods typically fall under the code. They are not goods descriptions checked by customs.
How to describe the goods in the export declaration
The goods description states the usual trade name of the goods and is precise enough for an unambiguous classification. Brand names and collective terms alone are not enough.
Include these details in the description:
- Connectors: which plugs or sockets on which ends, e.g. RJ45, SFP+, MC4 or PCIe.
- Use as the deciding feature: cable of a kind used for telecommunications (8544 42 10) or other cable (8544 42 90).
- Rated voltage in V. The subheading only applies up to 1,000 V.
- Cable type and construction, e.g. Cat.6A U/UTP, number of cores, shielding.
- Length per piece in m or cm.
Example wording
“Patch cable Cat.6A, U/UTP, with RJ45 plugs on both ends, length 10 m, for data transmission in telecommunications networks, rated voltage below 1,000 V”
Example for guidance, not a commitment by customs.
Too vague
“Cable with plug”
Intended use, connector type and voltage are missing. It remains open whether 8544 42 10, 8544 42 90 or, above 1,000 V, another subheading applies.
Example goods descriptions for each commodity code
This is what a complete goods description can look like: first the generic term from the customs tariff, then what the goods are, what they are made of and what they are used for. Adapt the example to your goods. The examples are in German, the language in which the export declaration is filed with German customs.
8544 42 10 Of a kind used for telecommunications
- Elektrische Leiter mit Anschlussstücken, für die Telekommunikation: Patchkabel Cat.6A, 10 m, acht verdrillte Kupferleiter, RJ45-Stecker, zum Verbinden von Netzwerkgeräten
- Elektrische Leiter mit Anschlussstücken, für die Telekommunikation: passives Stacking-Kabel 3 m mit SFP+-Steckern, Kupferleiter, zur Datenübertragung zwischen Netzwerk-Switches
- Elektrische Leiter mit Anschlussstücken, für die Telekommunikation: Telefonanschlusskabel 3 m mit TAE- und RJ11-Stecker, Kupferlitzen in PVC-Mantel, für Telefone und Router
8544 42 90
- Isolierte Kabel mit Anschlussstücken: PV-Anschlusskabel aus Kupferleitern mit MC4-Steckanschluss und Anschlussdose, für bis zu 1000 V DC, zum Anschluss von Photovoltaikmodulen
- Isolierte Kabel mit Anschlussstücken: geräteinternes Adapterkabel mit PCIe-Buchse und PCIe-Steckern, Kupferlitzen, 12 V, zur Stromversorgung von Grafikkarten in Computern
- Isolierte elektrische Leiter mit Anschlussstücken: Verlängerungskabel 10 m mit Schutzkontaktstecker und Kupplung, Kupferleiter mit Gummimantel, für Gartengeräte, 230 V
Examples for guidance, not a commitment by customs.
Not covered by 8544 42
- 8544 49
Insulated conductors up to 1,000 V without connectors, such as bulk cable, belong to 8544 49.
CN: Insulated (including enamelled or anodised) wire, cable (including coaxial cable) and other insulated electric conductors, whether or not fitted with connectors; optical fibre cables, made up of individually sheathed fibres, whether or not assembled with electric conductors or fitted with connectors – Other
- 8544 20
Coaxial cables belong to subheading 8544 20, even when fitted with connectors.
CN: Insulated (including enamelled or anodised) wire, cable (including coaxial cable) and other insulated electric conductors, whether or not fitted with connectors; optical fibre cables, made up of individually sheathed fibres, whether or not assembled with electric conductors or fitted with connectors – Coaxial cable and other coaxial electric conductors
- 8544 30
Ignition wiring sets and other wiring sets for vehicles, aircraft or ships are classified in subheading 8544 30.
CN: Insulated (including enamelled or anodised) wire, cable (including coaxial cable) and other insulated electric conductors, whether or not fitted with connectors; optical fibre cables, made up of individually sheathed fibres, whether or not assembled with electric conductors or fitted with connectors – Ignition wiring sets and other wiring sets of a kind used in vehicles, aircraft or ships
- 8544 60
Electric conductors for a voltage exceeding 1,000 V belong to subheading 8544 60.
CN: Insulated (including enamelled or anodised) wire, cable (including coaxial cable) and other insulated electric conductors, whether or not fitted with connectors; optical fibre cables, made up of individually sheathed fibres, whether or not assembled with electric conductors or fitted with connectors – Other electric conductors, for a voltage exceeding 1 000 V
- 8544 70
Fibre optic patch cables are optical fibre cables of subheading 8544 70.
CN: Insulated (including enamelled or anodised) wire, cable (including coaxial cable) and other insulated electric conductors, whether or not fitted with connectors; optical fibre cables, made up of individually sheathed fibres, whether or not assembled with electric conductors or fitted with connectors – Optical fibre cables
What to watch out for when exporting cables with connectors
- Export declaration from €1,000: If the goods value and transport costs together exceed €1,000 or the consignment weighs more than 1,000 kg, you need an export declaration to export to a country outside the EU. Whether this applies to your shipment is shown by the check Do I need an ABD?
- Dual-use goods: Some goods in this chapter can be dual-use items under the Dual-Use Regulation (EU) 2021/821. Their export then requires an authorisation from BAFA. Check this before exporting.
- Lithium batteries as dangerous goods: Lithium batteries count as dangerous goods in transport (UN 3480; contained in or packed with equipment UN 3481). This affects packaging and transport documents, not the commodity code. Clarify the requirements with your forwarder before shipping.
- Exit notification as evidence: After export you receive the exit notification. It is the evidence for the VAT-exempt export supply. Without it, the tax office can demand the VAT retrospectively.
Frequently asked questions about commodity code 8544 42
What is the commodity code for a patch cable?
A patch cable with RJ45 plugs is a cable of a kind used for telecommunications. It belongs to commodity code 8544 42 10. This also applies to passive stacking cables with SFP+ connectors between switches.
Do I need an export declaration to send cables to Switzerland?
Yes, if the goods value and transport costs together exceed €1,000 or the consignment weighs more than 1,000 kg. Below that, an oral declaration is often sufficient. Parcel carriers often require an ABD from a goods value of €750. Check this with your carrier before shipping.
What is the commodity code for a solar cable with MC4 connectors?
A connection cable for photovoltaic modules with MC4 connectors for no more than 1,000 V belongs to 8544 42 90. If the cable is rated for more than 1,000 V, such as 1,500 V, subheading 8544 60 applies.
What is the commodity code for a car wiring harness?
Wiring sets of a kind used in vehicles do not belong to 8544 42 but to subheading 8544 30. Single cables with connectors that are not a wiring set stay in 8544 42.
Other codes in 8544 and chapter 85
- 8544 11Of copper
- 8544 19Other
- 8544 20Coaxial cable and other coaxial electric conductors
- 8544 30Ignition wiring sets and other wiring sets of a kind used in vehicles, aircraft or ships
- 8544 49Other
- 8544 60Other electric conductors, for a voltage exceeding 1 000 V
- 8544 70Optical fibre cables
- 8543Electrical machines and apparatus, having individual functions, not specified or included elsewhere in this chapter
- 8545Carbon electrodes, carbon brushes, lamp carbons, battery carbons and other articles of graphite or other carbon, with or without metal, of a kind used for electrical purposes
All information without guarantee and without binding tariff information. Your details are checked when you create the export declaration in our application.