8536 69 – Plugs and sockets for a voltage not exceeding 1,000 V: connectors, pin headers, coaxial connectors
Subheading 8536 69 covers plugs and sockets for voltages up to 1,000 V other than lamp holders. It includes plugs and sockets, pin and female headers, coaxial and antenna connectors, circular connectors, adapters and socket blocks. The 8-digit code depends on what the connector is intended for. For coaxial cables 8536 69 10 applies, for printed circuits 8536 69 30, for all others 8536 69 90.
- CN description
- Electrical apparatus for switching or protecting electrical circuits, or for making connections to or in electrical circuits (for example, switches, relays, fuses, surge suppressors, plugs, sockets, lamp holders and other connectors, junction boxes), for a voltage not exceeding 1 000 V; connectors for optical fibres, optical fibre bundles or cables – Other
- Commodity codes
- 8536 69 108536 69 308536 69 90 · Status: Combined Nomenclature 2026
The 8-digit commodity codes of subheading 8536 69
In the export declaration you enter the 8-digit code.
| Code | CN description | Product examples |
|---|---|---|
| 8536 69 10 | For coaxial cables |
|
| 8536 69 30 | For printed circuits |
|
| 8536 69 90 | Other (other than 8536 69 10, 8536 69 30) |
|
The product examples show which goods typically fall under the code. They are not goods descriptions checked by customs.
How to describe the goods in the export declaration
The goods description states the usual trade name of the goods and is precise enough for an unambiguous classification. Brand names and collective terms alone are not enough.
Include these details in the description:
- Intended use: for coaxial cables (8536 69 10), for printed circuits on circuit boards (8536 69 30) or other purposes (8536 69 90). This separates the 8-digit codes.
- Design: plug, socket, coupler, adapter, pin or female header, socket outlet.
- Number of poles, pitch and mounting, e.g. 10-pole, 2.54 mm pitch, through-hole soldering or SMT.
- Rated voltage and current, e.g. 250 V and 16 A. The subheading only applies up to 1,000 V.
- Form of delivery: single item without cable; a cable fitted with a plug belongs elsewhere.
Example wording
“Connector for printed circuits [BRAND] [MODEL], 10-pole pin header, 2.54 mm pitch, for soldering onto circuit boards, 250 V, new”
Example for guidance, not a commitment by customs.
Too vague
“Plug”
It does not state whether the plug is intended for coaxial cables, for circuit boards or for another purpose. Which of the three 8-digit codes applies remains open. A cable with a plug would also be possible.
Example goods descriptions for each commodity code
This is what a complete goods description can look like: first the generic term from the customs tariff, then what the goods are, what they are made of and what they are used for. Adapt the example to your goods. The examples are in German, the language in which the export declaration is filed with German customs.
8536 69 10 For coaxial cables
- Steckvorrichtungen für Koaxialkabel: IEC-Antennenadapter, Buchse auf Stecker, Körper aus vernickeltem Messing, zum Verbinden von Koaxialkabeln an Fernsehgeräten
- Steckvorrichtungen für Koaxialkabel: F-Stecker zum Aufschrauben, aus Messing, für Koaxialkabel mit 7 mm Außendurchmesser, zum Anschluss an Satellitenanlagen
- Steckvorrichtungen für Koaxialkabel: BNC-Steckverbinder 50 Ohm, Gehäuse aus Messing mit PTFE-Isolierung, zum Anschluss von Koaxialkabeln an Messgeräten
8536 69 30 For printed circuits
- Steckvorrichtungen für gedruckte Schaltungen: Stiftleiste, zweireihig, 20-polig, Isolierkörper aus PBT mit vergoldeten Kontaktstiften, zum Einlöten in Leiterplatten
- Steckvorrichtungen für gedruckte Schaltungen: ZIF-Steckverbinder, 50-polig, Raster 0,5 mm, Gehäuse aus LCP, zur SMD-Montage für den Anschluss von Flachbandkabeln
- Steckvorrichtungen für gedruckte Schaltungen: Leiterplattensteckverbinder, abgewinkelt, 6-polig, Gehäuse aus Polyamid mit verzinnten Kontakten, zum Anschluss von Kabelsätzen an Steuerplatinen
8536 69 90
- Steckvorrichtungen: Schutzkontakt-Steckdose zum Unterputzeinbau, Gehäuse aus Thermoplast mit Messingkontakten, für 250 V und 16 A, für die Elektroinstallation in Wohngebäuden
- Steckvorrichtungen: Reiseadapter von Eurostecker auf US-Steckdose, Gehäuse aus Kunststoff mit Flachkontakten aus Messing, für 250 V, zum Anschluss von Elektrogeräten
- Steckvorrichtungen: Rundsteckverbinder M12, 4-polig, Gehäuse aus vernickeltem Zinkdruckguss, für 250 V, zum Anschluss von Sensorleitungen in Industrieanlagen
Examples for guidance, not a commitment by customs.
Not covered by 8536 69
- 8536 61
Lamp holders do not belong to 8536 69 but to subheading 8536 61.
CN: Electrical apparatus for switching or protecting electrical circuits, or for making connections to or in electrical circuits (for example, switches, relays, fuses, surge suppressors, plugs, sockets, lamp holders and other connectors, junction boxes), for a voltage not exceeding 1 000 V; connectors for optical fibres, optical fibre bundles or cables – Lamp holders
- 8536 70
Connectors for optical fibres and optical cables are classified in subheading 8536 70.
CN: Electrical apparatus for switching or protecting electrical circuits, or for making connections to or in electrical circuits (for example, switches, relays, fuses, surge suppressors, plugs, sockets, lamp holders and other connectors, junction boxes), for a voltage not exceeding 1 000 V; connectors for optical fibres, optical fibre bundles or cables – Connectors for optical fibres, optical fibre bundles or cables
- 8544 42
Cables already fitted with plugs are insulated conductors fitted with connectors of subheading 8544 42.
CN: Insulated (including enamelled or anodised) wire, cable (including coaxial cable) and other insulated electric conductors, whether or not fitted with connectors; optical fibre cables, made up of individually sheathed fibres, whether or not assembled with electric conductors or fitted with connectors – Fitted with connectors
- 8536 90 10
Terminal blocks, connecting terminals and crimp connectors for wires belong to commodity code 8536 90 10.
CN: Electrical apparatus for switching or protecting electrical circuits, or for making connections to or in electrical circuits (for example, switches, relays, fuses, surge suppressors, plugs, sockets, lamp holders and other connectors, junction boxes), for a voltage not exceeding 1 000 V; connectors for optical fibres, optical fibre bundles or cables – Connections and contact elements for wire and cables
- 8504 40
Adapters with a built-in power supply, e.g. with a USB charging port, are static converters of subheading 8504 40.
CN: Electrical transformers, static converters (for example, rectifiers) and inductors – Static converters
What to watch out for when exporting connectors
- Export declaration from €1,000: If the goods value and transport costs together exceed €1,000 or the consignment weighs more than 1,000 kg, you need an export declaration to export to a country outside the EU. Whether this applies to your shipment is shown by the check Do I need an ABD?
- Dual-use goods: Some goods in this chapter can be dual-use items under the Dual-Use Regulation (EU) 2021/821. Their export then requires an authorisation from BAFA. Check this before exporting.
- Lithium batteries as dangerous goods: Lithium batteries count as dangerous goods in transport (UN 3480; contained in or packed with equipment UN 3481). This affects packaging and transport documents, not the commodity code. Clarify the requirements with your forwarder before shipping.
- Exit notification as evidence: After export you receive the exit notification. It is the evidence for the VAT-exempt export supply. Without it, the tax office can demand the VAT retrospectively.
Frequently asked questions about commodity code 8536 69
What is the commodity code for a connector?
A connector for up to 1,000 V belongs to subheading 8536 69 if it is not a lamp holder. The 8-digit code depends on the use. Coaxial cables: 8536 69 10, printed circuits: 8536 69 30, all others: 8536 69 90.
Do I need an export declaration to send connectors to Switzerland?
Yes, if the goods value and transport costs together exceed €1,000 or the consignment weighs more than 1,000 kg. Below that, an oral declaration is often sufficient. Parcel carriers often require an ABD from a goods value of €750. Check this with your carrier before shipping.
What is the commodity code for a travel adapter?
A travel adapter without electronics, e.g. from a Europlug to US flat pins, is a plug-and-socket device of commodity code 8536 69 90. An adapter with a built-in power supply, e.g. a USB charging port, is a static converter of subheading 8504 40.
Does a USB or HDMI socket belong to 8536 69 30?
Only if it is intended for printed circuits, i.e. for soldering or press-fitting onto circuit boards. Sockets and plugs for cables or housings belong to 8536 69 90. State therefore the type of mounting.
Other codes in 8536 and chapter 85
- 8536 10Fuses
- 8536 20Automatic circuit breakers
- 8536 30Other apparatus for protecting electrical circuits
- 8536 41For a voltage not exceeding 60 V
- 8536 49Other
- 8536 50Other switches
- 8536 61Lamp holders
- 8536 70Connectors for optical fibres, optical fibre bundles or cables
- 8536 90Other apparatus
- 8535Electrical apparatus for switching or protecting electrical circuits, or for making connections to or in electrical circuits (for example, switches, fuses, lightning arresters, voltage limiters, surge suppressors, plugs and other connectors, junction boxes), for a voltage exceeding 1 000 V
- 8537Boards, panels, consoles, desks, cabinets and other bases, equipped with two or more apparatus of heading 8535 or 8536, for electric control or the distribution of electricity, including those incorporating instruments or apparatus of Chapter 90, and numerical control apparatus, other than switching apparatus of heading 8517
All information without guarantee and without binding tariff information. Your details are checked when you create the export declaration in our application.